Any electrician out there?

£0.00 @
I just fitted a 3 gang MK power socket which has a 13A fuse. The socket has 2 earth inputs, 1 live and 1 neutral. The cable in the socket only has 1 earth. Now i have connected the 3 cables and left … Read More
d84rk_knight Avatar
1w, 2d agoPosted 1 week, 2 days ago
I just fitted a 3 gang MK power socket which has a 13A fuse. The socket has 2 earth inputs, 1 live and 1 neutral. The cable in the socket only has 1 earth.

Now i have connected the 3 cables and left 1 earth input empty.

The problem is that 1 of the 3 sockets does not work. Have I dont something wrong in the wiring (maybe with the spare earth input) or is it a faulty unit?

I read somewhere that I need to take an earth cable from one earth input and into the other earth input to join them together??

Any help will be appreciated.
d84rk_knight Avatar
1w, 2d agoPosted 1 week, 2 days ago
Options
Best Answer
RxTx
I've never used these three gang sockets but could it be that the fuse just does the 3rd socket and that the fuse is missing or blown or that the fuse carrier isn't fully screwed in ?

I thought that but reading the spec the fuse protects all three sockets. If one socket does not work I suspect the switch is faulty. Have a go at working the switch a few times - if it doesn't work take the unit back for a replacement.

http://www.sparkydirect.co.uk/product/1334/829/K2737 WHI/MK-Logic-Plus-3-Gang-13-Amp-DP-Switched-Socket-Outlet-/index.html

All Responses

(13) Jump to unreadPost an answer
Responses/page:
#1
Probably faulty, However might be best to get an electrician to wire it up.
#2
Yes you should cable in earth sleeving to connect all the earth inputs. But all 3 sockets should work albeit unsafely without the earths connected. Are you installing a K2737 WHI?

I agree it could possibly be faulty. Get a replacement and try it.
#3
The two earth connections are fairly standard on MK sockets, both inputs are already connected with the socket body so there is no need to run an extra cable from the used to the unused connection.

From the MK manual - K781 WHI, K2657 WHI, K2737 WHI, K2746 WHI and K2757 WHI are fitted with two earth terminals on a common busbar to provide a double earth facility for use when installations require a high integrity protective connection as specified with in B S 7 6 7 1 : 2 0 0 8 .
#4
I've never used these three gang sockets but could it be that the fuse just does the 3rd socket and that the fuse is missing or blown or that the fuse carrier isn't fully screwed in ?
#5
RxTx
I've never used these three gang sockets but could it be that the fuse just does the 3rd socket and that the fuse is missing or blown or that the fuse carrier isn't fully screwed in ?

I thought that but reading the spec the fuse protects all three sockets. If one socket does not work I suspect the switch is faulty. Have a go at working the switch a few times - if it doesn't work take the unit back for a replacement.

http://www.sparkydirect.co.uk/product/1334/829/K2737 WHI/MK-Logic-Plus-3-Gang-13-Amp-DP-Switched-Socket-Outlet-/index.html
#6
I'd try replacing the fuse first
#7
Ok ive tried turning the switch on and off a few times and I noticed that power comes for a second a goes again. Im now thinking its a faulty switch.

Edited By: d84rk_knight on Jul 11, 2017 08:17: Spelling
#8
Sounds faulty or you haven't terminated the cables correctly you have probably screwed down onto the cable insulation rather than the copper , also get an electrician out to do this as it sounds like you have no idea what you are doing especially asking about the 2 earth terminals on the socket outlet.

Edited By: darksideby182 on Jul 11, 2017 09:13
#9
Just got and fitted a replacement. Works perfectly fine now.

No it wasnt screwed onto the insulation because the whole socket would not be working then. Wiring was perfectly correct.
It was definitely a faulty switch on one of the sockets.

All solved now. Thanks for you help guys.
#10
darksideby182
Sounds faulty or you haven't terminated the cables correctly you have probably screwed down onto the cable insulation rather than the copper , also get an electrician out to do this as it sounds like you have no idea what you are doing especially asking about the 2 earth terminals on the socket outlet.
I do know what Im doing. I was a faulty socket switch. I didnt screw onto the insulation coz that wouldnt allow the entire socket to work. 2 of the 3 sockets were working.
#11
Van1973
RxTx
I've never used these three gang sockets but could it be that the fuse just does the 3rd socket and that the fuse is missing or blown or that the fuse carrier isn't fully screwed in ?
I thought that but reading the spec the fuse protects all three sockets. If one socket does not work I suspect the switch is faulty. Have a go at working the switch a few times - if it doesn't work take the unit back for a replacement.http://www.sparkydirect.co.uk/product/1334/829/K2737 WHI/MK-Logic-Plus-3-Gang-13-Amp-DP-Switched-Socket-Outlet-/index.html
Did exactly this. Worked the switch a few times, it would come on for a second before going off. Replaced the entire socket and now works perfectly. Thanks.
#12
d84rk_knight
darksideby182
Sounds faulty or you haven't terminated the cables correctly you have probably screwed down onto the cable insulation rather than the copper , also get an electrician out to do this as it sounds like you have no idea what you are doing especially asking about the 2 earth terminals on the socket outlet.
I do know what Im doing. I was a faulty socket switch. I didnt screw onto the insulation coz that wouldnt allow the entire socket to work. 2 of the 3 sockets were working.
Ok having to ask about the earthing set up says otherwise. But you DIY heros always know best lol
#13
Put your tongue in there when you switch it on , the conducive nature of spit can sometimes free up a faulty switch. " I know what I'm doing", lol muhaha.

Post an Answer