nest thermostat wiring 2nd gen

£0.00 @ Nest
hi everyone. ive just had a new worcester 34cdi fitted and my nest thermostat only arrived today so i need a bit of help with the wiring. currently i havent for a programmer or thermostat connected to… Read More
aj1soad Avatar
7m, 1w agoPosted 7 months, 1 week ago
hi everyone. ive just had a new worcester 34cdi fitted and my nest thermostat only arrived today so i need a bit of help with the wiring. currently i havent for a programmer or thermostat connected to the boiler. in the boiler ST10 wiring the L and N are already connected but i need to find out how to connect the LR LS and NS cables. on the nest thermostat ive got L N 1 2 3 T1 T2.
1 is Satisfied (optional)
2 Common
3 Call for heat
which ones connect to where? i know that t1 and t 2 goes to the thermostat. thanks
Other Links From Nest:
aj1soad Avatar
7m, 1w agoPosted 7 months, 1 week ago
Options

All Responses

(1) Jump to unreadPost an answer
Responses/page:
#1
LS/NS in boiler go to heatlink L/N, link the L in the heatlink to 2 (you need to remove the pre-wired link from LS/LR so re-use this), then 3 goes to LR in the boiler.

Use 0.75 heat resistant flex for this.

Edited By: themorgatron on Sep 14, 2016 21:28

Post an Answer

You don't need an account to leave a response. Just enter your email address. We'll keep it private.

...OR log in with your social account

...OR comment using your social account

Thanks for your comment! Keep it up!
We just need to have a quick look and it will be live soon.
The community is happy to hear your opinion! Keep contributing!