DEWALT DWE4206L 115 mm 1010 W 110 V Mini Grinder £24.52 Amazon - HotUKDeals
We use cookie files to improve site functionality and personalisation. By continuing to use HotUKDeals, you accept our cookie and privacy policy.
Get the HotUKDeals app free at Google Play

Search Error

An error occurred when searching, please try again!

Login / Sign UpSubmit
481Expired

DEWALT DWE4206L 115 mm 1010 W 110 V Mini Grinder £24.52 Amazon

£24.52 @ Amazon
sweet price Dispatched within 1-2 months - vassy4u Read More
yoyelp Avatar
banned3m, 1w agoFound 3 months, 1 week ago
sweet price

Dispatched within 1-2 months
- vassy4u
More From Amazon:
×
Get the Hottest Deals Daily
Stay informed. Once a day, we'll send you the deals our members voted as the best.
Failed
yoyelp Avatar
banned3m, 1w agoFound 3 months, 1 week ago
Options

Top Comments

(2)
23 Likes
Let me guess.
You got caught googling Grinder and felt obliged to post this to cover your tracks.

;)

Edited By: FREEZIN_WOLF on Apr 18, 2017 07:44
5 Likes
I just purchased this.

What does it do? What is it used for?

All Comments

(68) Jump to unreadPost a comment
Comments/page:
Page:
3 Likes #1
If only it was 240V.
#2
Brilliant deal, ordered.

Cheers.
#3
callum84
Brilliant deal, ordered.

Cheers.


65.19.
#4
kayc61
callum84
Brilliant deal, ordered.
Cheers.
65.19.
Look on the right hand panel for Amazon price.
#5
Why is it 110v? American? Must we use a transformer to operate this?
4 Likes #6
vibz1991
Why is it 110v? American? Must we use a transformer to operate this?
Not american.

110v also called reduced low voltage. Its mandatory on most sites and lot of workplaces.

Yes you would need a 110v transformer.
#7
Good price if you have 110v transformer already, otherwise extra cost.
#8
Does this come with discs?



Edited By: Teqnophile on Apr 18, 2017 09:42: update
1 Like #9
vibz1991
Why is it 110v? American? Must we use a transformer to operate this?


110v is for safety reasons. The chance of shock is much lower with 110v than with mains voltage.

Remember though, Voltage jolts, current kills :/
23 Likes #10
Let me guess.
You got caught googling Grinder and felt obliged to post this to cover your tracks.

;)

Edited By: FREEZIN_WOLF on Apr 18, 2017 07:44
#11
Super price, nice find OP
#12
Brilliant price for 110v.
#13
1-2 month delivery time. Ouch! Very very cheap though
#14
excellent! cheers!!
#15
Shame not 240v
#16
Ordered 2 Thanks
#17
Great deal,definitely don't need tho...ordered!
#18
Mispriced, but bought anyway. Awaiting cancellation email.
2 Likes #19
Darzen
Ordered 2 Thanks
That'll be almost 240v then
:D
2 Likes #20
hamsterboy
vibz1991
Why is it 110v? American? Must we use a transformer to operate this?
110v is for safety reasons. The chance of shock is much lower with 110v than with mains voltage.
Remember though, Voltage jolts, current kills :/
A single phase site transformer will have an earthed centre tap so the highest voltage to earth you can receive as an operator is 55V.
HSE guidance still considers this to be safer than 230V protected by a Residual Current Device.
#21
will it go through bike locks
2 Likes #22
GDB2222
Mispriced, but bought anyway. Awaiting cancellation email.

Amazon dont generally cancel 'mis priced' they leave you waiting for about 3 months and then tell you they can't get it.
4 Likes #23
londonguy
will it go through bike locks
Yes but your need to provide a power supply and transformer may slow your getaway down...unless you have a reeeeeely long lead :)
#24
parsimony
hamsterboy
vibz1991
Why is it 110v? American? Must we use a transformer to operate this?
110v is for safety reasons. The chance of shock is much lower with 110v than with mains voltage.
Remember though, Voltage jolts, current kills :/
A single phase site transformer will have an earthed centre tap so the highest voltage to earth you can receive as an operator is 55V.
HSE guidance still considers this to be safer than 230V protected by a Residual Current Device.

Correct. Voltage is basically "electrical pressure", if it cannot overcome the resistance to earth (say your work boots) you won't get a shock. The current will actually be higher in a 110v appliance of identical power (Watts) than it's 230v equivalent. Is something of a moot point though because a shock as little as 60ma can stop your heart if taken across your core...hence the insistence on 110v on site. Even 30millisec 230v jolt can finish you if your unlucky, which is why RCD protection is not all that.


Edited By: Tyranicus66 on Apr 18, 2017 17:18
#25
Plenty of stolen 110v transformers at your local cash converters (_;)
2 Likes #26
hamsterboy
vibz1991
Why is it 110v? American? Must we use a transformer to operate this?
110v is for safety reasons. The chance of shock is much lower with 110v than with mains voltage.
Remember though, Voltage jolts, current kills :/

That is fundamentally wrong. In fact with the way the 110V tool transformer supplies the power, you are actually twice as likely to get a shock because there are two "live" conductors rather than one. The reason why it is overall safer is because the live conductors are only at 55V (to earth) rather than 240V.

Edited By: madasadog on Apr 18, 2017 19:10
1 Like #27
vibz1991
Why is it 110v? American? Must we use a transformer to operate this?

It expects 110V 50Hz, which is what is supplied by the common yellow "tool transformers" you may have seen on building sites.

They are wired with two live conductors at 55V and 180 degrees out of phase, with a centre tapped earth. The idea is that if the cable insulation is damaged and a conductor becomes exposed and someone comes into contact with it, they only receive 55 volts rather than 240. The difference is substantial and can very easily be the difference between a rather painful jolt, and death.

Edited By: madasadog on Apr 18, 2017 19:09
#28
parsimony
hamsterboy
vibz1991
Why is it 110v? American? Must we use a transformer to operate this?
110v is for safety reasons. The chance of shock is much lower with 110v than with mains voltage.
Remember though, Voltage jolts, current kills :/
A single phase site transformer will have an earthed centre tap so the highest voltage to earth you can receive as an operator is 55V.
HSE guidance still considers this to be safer than 230V protected by a Residual Current Device.

It is safer, and you would normally always use an RCD with a tool transformer anyway
#29
FREEZIN_WOLF
Let me guess.
You got caught googling Grinder and felt obliged to post this to cover your tracks. ;)
That is superb but makes me think that has happened to you in the past or you have great wit ---- off to check your previous deals ;)
5 Likes #30
I just purchased this.

What does it do? What is it used for?
#31
heat! dammit just got the makita 115 for £60.
#32
if anyone is interrested, with a diamond blade this thing will cut paving slabs easily. However you will have to cut both sides but no biggy.
#33
captain_cab
heat! dammit just got the makita 115 for £60.
I'll take a Makita over a DeWalt any day of the week. I think they've gone right down the pan in the last few years, although to be fair so has much of the competition - most seem to have introduced an 'entry level' range that trades on the brand name but is built right down to a price.
#34
Absolute bargain...God knows why a painter wants one though!!
#35
I have ordered one says delivery between 8th to 28th May just see if it arrives thanks:)
#36
Are these any good for clearing cement between bricks before repointing?
#37
patrick_000
Are these any good for clearing cement between bricks before repointing?

If you need to grind out the existing mortar, does it really need replacing.

Bad pointing should be removed using a hand tool manually to avoid damaging the bricks.

Reprinting with a cement based mortar can do more harm than good on old houses that were originally built using a lime mortar.
#38
Teqnophile
patrick_000
Are these any good for clearing cement between bricks before repointing?
If you need to grind out the existing mortar, does it really need replacing.
Bad pointing should be removed using a hand tool manually to avoid damaging the bricks.
Reprinting with a cement based mortar can do more harm than good on old houses that were originally built using a lime mortar.

Yep, I've been enjoying getting the cement out from our old stone walls left there by someone who butchered it with random dollops of the stuff!

All by hand too. Takes a while but better then damaging the stone!

Edited By: northlondon01 on Apr 18, 2017 22:42
#39
Speculator
kayc61
callum84
Brilliant deal, ordered.
Cheers.
65.19.
Look on the right hand panel for Amazon price.


thank you. ordered one. cheers.
#40
Speculator
kayc61
callum84
Brilliant deal, ordered.
Cheers.
65.19.
Look on the right hand panel for Amazon price.


cheers. ordered now. thanks again

Post a Comment

You don't need an account to leave a comment. Just enter your email address. We'll keep it private.

...OR log in with your social account

...OR comment using your social account

Top of Page
Thanks for your comment! Keep it up!
We just need to have a quick look and it will be live soon.
The community is happy to hear your opinion! Keep contributing!