5 Likes #1
just remember to unwind all the lead when in use or it will keep tripping as the cable gets hot.
1 Like #2
good find op, heat added
1 Like #3
chelseablue
just remember to unwind all the lead when in use or it will keep tripping as the cable gets hot.


It will act as a big inductor if not unwind
1 Like #4
Thanks :)
2 Likes #5
sam_of_london
chelseablue
just remember to unwind all the lead when in use or it will keep tripping as the cable gets hot.
It will act as a big inductor if not unwind
Not only that Sam, when wound, there is less surface area for heat dissipation which will cause the conductor's temp to rise and so increase resistance, which increases the temp rise further ..... possibly resulting in a degradation of insulation and the possibility of short circuits and even fire.
#6
Rhead
sam_of_london
chelseablue
just remember to unwind all the lead when in use or it will keep tripping as the cable gets hot.
It will act as a big inductor if not unwind
Not only that Sam, when wound, there is less surface area for heat dissipation which will cause the conductor's temp to rise and so increase resistance, which increases the temp rise further ..... possibly resulting in a degradation of insulation and the possibility of short circuits and even fire.

The reel has the thermal cut-out switch, which is capable of cutting power if the reel is getting close to a temperature level whereby the PVC outer of the cable might be at risk of melting....
3 Likes #7
This is good if you need a extension with 45 meters or you don't mind winding it all out and back in again. I got about 15mins use before the thermal cut out operated, that was half unwound and using a medium size lawn mower. Then I let the missus loose who unwound the whole cable and it didn't cut out till she run over the cable.
4 Likes #8
sam_of_london
chelseablue
just remember to unwind all the lead when in use or it will keep tripping as the cable gets hot.
It will act as a big inductor if not unwind
... not that it particularly matters on a hot deals site, but the coil will not act as an inductor because there is no secondary coil to induce a current into (unless you haplessly leave another conductor right next to it and connected to a load, which I think one would have to admit would be an unlikely circumstance).
There will be a significant heating effect due to the current in the cable (I^2.R), so if a fairly large mower with a 2kW motor was drawing 8A, and the live + neutral flexes had a combined resistance of 1 ohm (a bit higher than one might expect for 90m of flex, but not inconceivable) then there would be 64W trying to escape from a tightly wound cable drum - or about the same as an incandescent light bulb inside the wound cable drum, which would get pretty hot if not unwound to allow that 64W to dissipate.
It is good that the cable drum has a thermal cut out device, but if that does not operate for some reason than it is unlikely that the overcurrent device in the consumer unit (probably a 32A MCB, or even worse a fuse) would operate before the fire starts in the cable drum - so always fully unwind the cable, even for fairly small electrical loads.


Edited By: othen on Oct 06, 2016 07:41: Another spelling mistake.
#9
othen
sam_of_london
chelseablue
just remember to unwind all the lead when in use or it will keep tripping as the cable gets hot.
It will act as a big inductor if not unwind
... not that it particularly matters on a hot deals site, but the coil will not act as an inductor because there is no secondary coil to induce a current into (unless you haplessly leave another conductor right next to it and connected to a load, which I think one would have to admit would be an unlikely circumstance).
There will be a significant heating effect due to the current in the cable (I^2.R), so if a fairly large mower with a 2kW motor was drawing 8A, and the live + neutral flexes had a combined resistance of 1 ohm (a bit higher than one might expect for 90m of flex, but not inconceivable) then there would be 64W trying to escape from a tightly wound cable drum - or about the same as an incandescent light bulb inside the wound cable drum, which would get pretty hot if not unwound to allow that 64W to dissipate.
It is good that the cable drum has a thermal cut out device, but if that does not operate for some reason than it is unlikely that the overcurrent device in the consumer unit (probably a 32A MCB, or even worse a fuse) would operate before the fire starts in the cable drum - so always fully unwind the cable, even for fairly small electrical loads.

Thanks for the clear explanation. I can relate some of this stuff to the some of the school Physics I did and can remember many moons ago. It's always helpful when someone explains why something needs to be done a certain way.
#10
Good practice but really depends what you have running off the end of the cable reel (power/current draw) as to whether it all needs to be uncoiled or not. Thermal cut out is handy as this will decide for you when you start to overheat the environment but better to err on the safe side.
#11
othen
sam_of_london
chelseablue
just remember to unwind all the lead when in use or it will keep tripping as the cable gets hot.
It will act as a big inductor if not unwind
... not that it particularly matters on a hot deals site, but the coil will not act as an inductor because there is no secondary coil to induce a current into (unless you haplessly leave another conductor right next to it and connected to a load, which I think one would have to admit would be an unlikely circumstance).
... not that it particularly matters on a hot deals site, but whilst I think you've overlooked that the coiled wire is effectively a secondary wire to itself - i.e. each loop induces a current in every other. This is "self-induction" and is the fundamental property of any coil. What you are talking about is "secondary" induction. All basic "inductors" that you buy or make only have two connections but are definitely still inductors and possess inductance.

That said I'm unconvinced that the inductance of a cable drum that is wound up will have any effect on how hot it gets? This is because any impedance it adds is reactive (rather than resistive) but also because the wiring is "balanced" (e.g. like a "twisted pair"). The current fluctuations in the live wire are matched with an equal and opposite fluctuation in the neutral wire for the return path and the wiring cross-section and spacing is constant - the net magnetic field is (to a first approximation) zero and any change to the impedance through winding the cable up will be minimal.

I think you are spot on with your explanation for the source of the heat though - i.e. the cable resistance! The wire is possibly dissipating around 2W/m and that isn't heat that you want to concentrate in one small area!


Edited By: qyestionmark on Dec 09, 2016 08:54: .

Post a Comment

You don't need an account to leave a comment. Just enter your email address. We'll keep it private.

...OR log in with your social account

...OR comment using your social account

Top of Page
Thanks for your comment! Keep it up!
We just need to have a quick look and it will be live soon.
The community is happy to hear your opinion! Keep contributing!