A proper plug socket. Not like the white plastic council house things commonly posted on here.
Are these easy to install diy. Was thinking of maybe getting a usb one too . I would t need any extra wires would I
Are there any usb ones on offer too?
wakkaday21/04/2020 22:08

Are these easy to install diy. Was thinking of maybe getting a usb one too …Are these easy to install diy. Was thinking of maybe getting a usb one too . I would t need any extra wires would I


Possibly need to earth the socket to the back box.
wakkaday21/04/2020 22:08

Are these easy to install diy. Was thinking of maybe getting a usb one too …Are these easy to install diy. Was thinking of maybe getting a usb one too . I would t need any extra wires would I


No
JmehNottsCountyFC21/04/2020 22:24

Possibly need to earth the socket to the back box.


Yes, you should do if it's a metal back box
wakkaday21/04/2020 22:08

Are these easy to install diy. Was thinking of maybe getting a usb one too …Are these easy to install diy. Was thinking of maybe getting a usb one too . I would t need any extra wires would I


Unless you have been trained how to properly test ring main circuits and know what you are doing that could be very dangerous.
wakkaday21/04/2020 22:08

Are these easy to install diy. Was thinking of maybe getting a usb one too …Are these easy to install diy. Was thinking of maybe getting a usb one too . I would t need any extra wires would I


In simple yes, just make sure to take the correct safety precautions. youtube.com/wat…VJ8
Wanted to get set of various sockets, but only few items have free delivery - even if you have item with free delivery in the basket you have to pay for delivery if there is item that doesn't have the offer :/
gary.broadbent21/04/2020 23:00

Yes, you should do if it's a metal back box


Why?

Can you point to the reg that says back boxes have to be earthed (no you cant because it does not exist)

Surface boxes have to be earthed

More 'experts' spreading misinformation
This is the cheapest I have seen these even with my discount at the wholesalers I would pay around £4.50 plus VAT for these
Nonsense about earthing the backbox.. and do NOT try to replace yourself, takes one wrong label on fuse board to kill you. Its really that simple. Hire a proffesional.
gap3022/04/2020 11:15

Why? Can you point to the reg that says back boxes have to be earthed (no …Why? Can you point to the reg that says back boxes have to be earthed (no you cant because it does not exist)Surface boxes have to be earthedMore 'experts' spreading misinformation


Please show me the reg that says metal doesn't have to be earthed fellow expert.
gap3022/04/2020 11:15

Why? Can you point to the reg that says back boxes have to be earthed (no …Why? Can you point to the reg that says back boxes have to be earthed (no you cant because it does not exist)Surface boxes have to be earthedMore 'experts' spreading misinformation


It's called belt and braces.

Every decent and competent electrician will always attach a fly lead from the back box to a metal faced socket.

If you rely on a machine screw to earth a back box and a metal face plate socket, then you are basically cutting corners regardless of whether it's in the reg's or not.

There's no excuse for shortcuts.
JmehNottsCountyFC22/04/2020 22:09

It's called belt and braces.Every decent and competent electrician will …It's called belt and braces.Every decent and competent electrician will always attach a fly lead from the back box to a metal faced socket.If you rely on a machine screw to earth a back box and a metal face plate socket, then you are basically cutting corners regardless of whether it's in the reg's or not.There's no excuse for shortcuts.


niceic approved contractor never earthed a socket back box in my life and been doing this for 25 years

Theres no excuse for shortcuts again show me the reg that says you have to earth back boxes

Belt and braces lol i would wipe the floor with you self rightous idiot

AGAIN SHOW ME THE REG THAT SAYS YOU HAVE TO EARTH BACK BOXES ARE YOU STUPID

Why would you do something that is not required by the regs are you mental
Post a comment