Something for the builders and sparkies.

Not for most, these usually sell for over £40.

22-module split load insulated consumer unit. Flexible busbar. BS EN 60439-3.

100A Main Switch

1 x 80A 30mA RCD

18-Way (22-Module), 10+11 Way Max

Modern Stylish Design with Curved, Smooth Profile

Fast Installation

Fast Metal DIN Rail Removal

Fitted Spirit Level

Easy Fit & Easy Clean Cover

Backed Out & Retained Combi Terminal Screws

15 Comments

Please note these most probably will not comply with the 3rd amendment to the 17th edition regs. Which states all CUs to be made of non combustible material. So as of Jan 2016 no sparky should be installing these.

Strictly speaking you could use this, but it would need to be mounted within a non-combustible box, observing the same requirements for location and environment etc
Given the necessity for both access to the unit (door) and ensuring that door [seal] met fire requirements, it's never worth the £50 you're trying to save over a compliant distribution unit.

Edited by: "steveex" 26th Sep 2016

To be honest its a cheap way to get the main switches

These can still be used in commercial properties

Banned

How many switches does it come with?

Also 17th edition split load for £17.99
screwfix.com/p/1…541
Wouldn't use it myself, but the 2 RCD's are worth more than £17.99.
Edited by: "Derek_Duval" 26th Sep 2016

gr8t1

Please note these most probably will not comply with the 3rd amendment to … Please note these most probably will not comply with the 3rd amendment to the 17th edition regs. Which states all CUs to be made of non combustible material. So as of Jan 2016 no sparky should be installing these.


Single RCD so not even 17th edition pre 3rd amendment.

Edited by: "Derek_Duval" 26th Sep 2016

Would you need separate MCBs to make a functional consumer unit?

The premise of split load being dual governing RCDs. You could use this board if you only had two or three circuits to distribute to which discrimination was not a factor (and obviously no smoke or fire alarm circuit)
Technically, under some situations this board CAN be made compliant. In reality it is never worth the effort. As said elsewhere, bought for spares etc (but even that is a regulatory minefield unless identical replacement parts)
Edited by: "steveex" 27th Sep 2016

maj2509

Would you need separate MCBs to make a functional consumer unit?


yes

have had 3 faulty rcd's from 7 consumer units made from BG, so make sure you keep your receipt .

AzeemB

yes


Thank you. Can this be used in a single phase wiring set up?

maj2509

Thank you. Can this be used in a single phase wiring set up?



i'm not an electrician

but i believe so.

However there's some new requirement to install metal consumer units now and split load with 2 rcds etc. I think having 2 rcds is quiet good idea anyway

How much do rcd's cost?

Anywhere cheap?